Title: Sistem Daring Transformator Monitoring Menggunakan Metode Analisis Gas Terlarut
Authors: Ridho, Ahmad
Keywords: minyak transformator;DGA;kegagalan minyak transformator;gas terlarut pada minyak;transformer oil;transformer oil failure;dissolved gas in oil
Issue Date: 28-May-2024
Abstract: Salah satu penyebab kerusakan gardu induk adalah kegagalan isolasi peralatan. Transformator terlalu panas. Overheating seringkali disebabkan oleh berbagai faktor yang salah yang lainnya adalah kelebihan beban. Arus lebih pada trafo akan menyebabkan tegangan naik temperatur pada minyak trafo dapat menyebabkan kerusakan pada isolasi minyak trafo. Untuk menjaga keandalan transformator, diperlukan pengujian untuk mengetahui kondisinya transformator awal. Cara pengujian untuk mengetahui kondisi trafo adalah dengan menguji oli trafo dengan menggunakan metode Dissolved Gas Analysis (DGA) sesuai dengan IEC 60599-2007. Dalam metode DGA, digunakan tiga metode interpretasi: metode Total Dissolved Combustible Gas (TDCG), metode gas kunci, dan metode segitiga Duval. Hasil percobaan menggunakan metode TDCG sebesar 1678,02 ppm yang menunjukkan trafo berada pada kondisi 2 yang berarti nilai TDCG mulai tinggi. Sementara itu, dengan menggunakan metode Key-Gas, trafo terdeteksi terdapat corona pada minyaknya akibat konsentrasi gas H2 yang mencapai 97%. Dengan menggunakan metode segitiga Duval, nilai konsentrasi gas CH4 sebesar 100% berada pada zona Partial Discharge (PD). Dari ketiga cara tersebut dapat disimpulkan bahwa trafo harus dirawat satu bulan sekali, dimana prosedur pengoperasiannya memerlukan ketelitian ekstra, analisa setiap gas dan penentuan beban ijin transformator.
One of the causes of substation damage is equipment insulation failure.Transformer overheating. Overheating is often caused by various wrong factors, one of which is overload. Overcurrent in the transformer will cause the voltage to rise, the temperature in the transformer oil can cause damage to the transformer oil insulation. To maintain the reliability of the transformer, testing is required to determine the condition of the initial transformer. The test method to determine the condition of the transformer is to test the transformer oil using the Dissolved Gas Analysis (DGA) method in accordance with IEC 60599-2007. In the DGA method, three interpretation methods are used: the total dissolved combustible gas (TDCG) method, the key gas method, and the Duval triangle method. The experimental results using the TDCG method were 1678.02 ppm which showed that the transformer was in condition 2, which means the TDCG value was starting to be high. Meanwhile, using the Key Gas method, the transformer was detected to have corona in its oil due to the H2 gas concentration reaching 97%. Using the Duval triangle method, the CH4 gas concentration value of 100% is in the partial discharge (PD) zone. From these three methods, it can be concluded that the transformer must be maintained once a month, where the operating procedure requires extra precision, analysis of each gas and determining the permit load of the transformator.
URI: https://repository.uksw.edu//handle/123456789/33301
Appears in Collections:T1 - Computer Systems

Files in This Item:
File Description SizeFormat 
T1_622017007_Judul.pdf766.28 kBAdobe PDFView/Open
T1_622017007_Isi.pdf
  Until 9999-01-01
764.17 kBAdobe PDFView/Open
T1_622017007_Daftar Pustaka.pdf399.51 kBAdobe PDFView/Open
T1_622017007_Lisensi dan Embargo.pdf
  Restricted Access
316.18 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.